Pre select counter/ high frequency monitor dislay and count a pre-set number of pulses dislay and monitor frequencies up to 10000Hz


R1901.30 

Learn More


These devices incorporate 1 relay which may be configured for any mode. COUNTER, RPM, Freq, PPh. 


ADJUSTABLE PARAMETERS:


FUNCTION:                                                        counter/frequency
SET POINT:                                                       1-49999 pulses
RELAY OUTPUT:                                                continous/pulse
REVERSE RELAY (relay status after counting): open/close
PRE-SCALE (pulses/count):                             1-200 pulses
POST-SCALE (count/pulses):                            1-200
INPUT PULSE SPEED:                                        mechanical/fast
PULSE EDGE (leading/trailing):                        close/open
KEYPAD AND MENU LOCK


Specifications:


Input range:                           0-9999 pulses,0-9999 RPM,0-5000Hz, 0-9999 pulses per hour
Maximum display value:         9999
Pre-scale:                               1-1000 pulses
Post-scale:                             1-1000
Decimal pointer:                     9999, 9.999, 99.99, 999,9
Accuracy:                                Counter mode : 100%
Freq, RPM,PPh : ±0.05%
Display Resolution:                Counter: 0.001 to 9999
Freq, RPM, PPh: 1
Input voltage:                         ±15% of rated voltage
Led indication:                        Relay status
Reset time:                             0.5 sec (power supply reset) 0.05 sec (reset pulse)
Response time:                       Counter: <0.02s
Freq, RPM, PPh: <1.1s
Input frequency                      “FASt”: 0-8000 Hz “SLO”: 0-5 Hz

Pulse source type mechanical switch or NPN proximity

All parameters are saved to non-volatile eeprom memory, thus eliminating the need to re-program after a power failure

incorporates a crystal oscillator to maintain accurate timing